Public sector

Hospital operating theatre

Sterility and leakage current decide what may be in the room, and the computer is not allowed to be.

Area
KVM & VTC
Architecture patterns
1
Products used
3

The problem

What makes it hard

The computer must not stand in the theatre for hygiene reasons — it cannot be disinfected, it blows air, it collects dust. The surgeon nevertheless needs images, records and the picture archive at the table.

Latency. A surgeon will not accept delay in an image path. The catalogue says “minimal latency” but gives no figure. Beyond that, a touch screen in a sterile environment needs a wipe-and-cover procedure that no product solves.

How it is built

Remote compute over HDBaseT fiber

The link carries USB and two-way audio, which moves the security boundary away from where people assume it is.

See the full pattern
The link carries USB and two-way audio. The security boundary is not where people assume.WorkstationCompute roomDisplayPeripheralsHDBaseT card moduleClientvideo, audio, USB,Ethernet, controltwo-way — theboundary is nothere
The link carries USB and two-way audio. The security boundary is not where people assume.WorkstationCompute roomDisplayPeripheralsHDBaseT card moduleClientvideo, audio,USB, Ethernet,controltwo-way — the boundary isnot here
The link carries USB and two-way audio. The security boundary is not where people assume.

In the catalogue

Equipment from the catalogue

Built from: Card Module FO USB 2.0 Receiver LC 60-00-7356 (42-106), Monitor 55" Touch 60-00-7729 and KVM Monitor 24" HDBaseT 60-00-8677.

Standard

Card Module FO USB 2.0 Receiver LC

Intended for use with Fibersystem’s Rack Module FO USB 2.0 Transceiver, 60-00-7357 with M-number F3785-000091…

Product no 60-00-7356 (42-106)

TEMPEST Level A · RÖS U1

Monitor 55" Touch

Screen size
55”
Optimal (recommended) resolution
3840 x 2160 @ 60 Hz
Display area
1210 x 680 (WxH) mm

Product no 60-00-7729

TEMPEST Level A · RÖS U1

KVM Monitor 24" HDBaseT

Optical system budget
Depends on type of SFP
Fiber optic connector
LC

Product no 60-00-8677

Reading and references

Explained in

Named customer references are not published. What we can show is the solution area this environment belongs to, and the reasoning behind the design.

Sector

Environments

Environments with the same problem

The technology is the same; the buying process usually is not.

Hands soldering a circuit board under a work lamp

Next step

Describe your environment

If yours is close to this one but not the same, that difference is usually where the design decisions are. Tell us what it looks like.

Verified credentials

All certifications