Pattern KV-E

The dual-use meeting room

What is disconnected, what is sealed, and what has to be physical when the same room is used at two levels the same day.

Area
KVM & VTC
Products used
10

How it is built

The changeover is physical and documented. It cannot be a setting in a control system.Low levelThe roomHigh levelOpen equipmentChangeover checklistSealingApproved equipmentphysicaldisconnectiondocumentedchangeoverno path without thechangeover
The changeover is physical and documented. It cannot be a setting in a control system.Low levelThe roomHigh levelOpen equipmentChangeover checklistSealingApproved equipmentphysical disconnectiondocumented changeoverno path withoutthe changeover
  • Data path
  • Path that does not exist
The changeover is physical and documented. It cannot be a setting in a control system.

How it works

The same room is used at two levels on different days, with a documented physical changeover in between.

The changeover cannot be a setting

It is a list of things that are disconnected, removed, sealed and verified — by a person, with a record. A control system that claims to have done it is a control system that can be wrong, and nobody would find out.

What has to be physical

Anything whose state cannot be seen from the room. Cables that come out, devices that are removed, seals that are broken and replaced with a record of who did it and when.

The time it takes is a design parameter

A changeover that takes an hour is a changeover that gets skipped when the next meeting is in twenty minutes. Measure it, state it, and design it down.

In the catalogue

Equipment from the catalogue

Standard

Secure Key Switch

Control of VTC Codec Switches in VTC Systems.

Product no 60-00-7996

TEMPEST Level A · RÖS U1

VTC 55" Internal Codec

Screen size
55 inches
Display area
1210 x 680 (WxH) mm
Brightness, typical
500 cd/m²

Product no 60-00-9164 (60-00-9186 SM)

TEMPEST Level B · RÖS U2

HDMI Diode

The Fibersystem HDMI Diode protects sensitive systems by ensuring that video and audio can only travel in one…

Product no 60-00-9155

TEMPEST Level A · RÖS U1

Codec Switch

Certified for both TEMPEST Level A and RÖS U1 for protection against intercepting signals and is designed to…

Product no 60-00-7829

TEMPEST Level A · RÖS U1

Tower Workstation 21"

TEMPEST Level A and RÖS U1 certified all-in-one computer featuring an integrated 21” monitor, webcam…

Product no 60-00-7883

Standard

Secure USB Disconnect Desktop

Dimensions
38 x 100 x 100 (HxWxD) mm
Weight
300 Gram

Product no 60-00-0234

TEMPEST Level A · RÖS U1

Secure Speaker

To allow monophonic and stereophonic sound reproduction with low distortion in the frequency range of 45 Hz…

Product no 60-00-8054

TEMPEST Level A · RÖS U1

Document Camera Level A

Connection
IEC 320-C14
Power consumption, typical
12 W
Dimensions
625 x 430 x 435 (HxWxD) mm

Product no 60-00-7776

Standard

VTC 55" Floor Stand Motorized

Motorized height-adjustable floor stand for the VTC 55" secure video conference system.

Product no 60-00-7684

Hands soldering a circuit board under a work lamp

Next step

Designing something that is not here?

Send us the constraints. We build from idea to certified end product, and most of what is in the catalogue started that way.

Verified credentials